20' CONTAINER STATIC CALCULATION
The static calculation is used for structural engineering tasks involving static or quasi-static loads. For economic reasons, there is also an effort to describe non-static loads in terms of equivalent quasi-static loads.
LIGHTNING PROTECTION
PRELIMINARY STUDY
To effectively protect a space from lightning strikes, it must be enclosed within a metallic, fully continuous, and grounded enclosure (Faraday cage). When lightning strikes, the current is conducted safely to the ground through the enclosure, without creating potential differences inside the protected space that could cause air breakdowns in the form of an electric arc.
AIR CONDITIONING STUDY
Cooling Load Calculation
This study was carried out according to the Carrier methodology, also following the guidelines of 2425/86 TOTEE, and utilizing the following supplementary tools:
FIRE SAFETY PRE-STUDY
Preliminary Study of Passive Fire Protection
Integrated System for Separation, Compression, and Storage of Recyclable Waste General This study has been prepared in accordance with Presidential Decree 71 – “Building Fire Protection Regulation” (Government Gazette 32, Issue A, 17.2.1988), Article 8.
SOUND INSULATION PRE-STUDY
This study has been conducted in accordance with Article 12 of the Building Code (Decision 3046/304 of 30.1/3.2.1989, Government Gazette 59D), taking into account the following supplementary materials.
INSULATION / THERMAL INSULATION
PRE-STUDY
The study has been conducted in accordance with the Thermal Insulation Regulation (Government Gazette 362/4.7.79) as well as the Guidelines of the Ministry of Public Works for the preparation of thermal insulation studies (19/9/78 A.P. 26354/476).
ELECTRICAL PRE-STUDY
Installation Calculation Report
This study has been conducted in accordance with the Hellenic Standard ELOT HD 384 – "Requirements for Electrical Installations", using the following supplementary tools
WATER SUPPLY PRE-STUDY
This study concerns the installation of water supply networks. The study was prepared in accordance with T.O.T.E.E. 2411/86, taking into account the following references:
a) Domestic Sanitary Installations – K. Schulz
b) Regulations for Internal Plumbing Installations
c) Operating Regulations of the EYDAP Water Supply Network
d) ELOT and DIN Standards
ARCHITECTURAL STUDY
Green Kiosk – Technical Report
Project: Integrated System for Sorting, Compressing, and Storing Recyclable Waste
Project Owner: Municipality of Naxos and Small Cyclades
Architectural Study: Foivos Skroubelos
NATIONAL TECHNICAL UNIVERSITY OF ATHENS (NTUA)
On the floor, a 50 mm insulation layer of type DOW Floormate 500 is installed, above which a 22 mm plywood base is constructed, screwed onto the steel floor beams of the container.
The interior floor finishing is applied throughout the entire Green Kiosk.
PROJECT STRUCTURAL STUDY
Static Calculation
Responsible Declaration
By the Designer and Supervising Engineer
Of the Structural Works